technical knowledge

What are the requirements for the installation location of the cooling tower

The installation location of the cooling tower has the following requirements: Ventilation requirements The cooling tower should be installed in a place with sufficient air inlet volume to ensure sufficient air flow into the tower. The distance between the air inlet side and the building should be greater than 1000mm to avoid poor ventilation affecting […]

What are the requirements for the installation location of the cooling tower Read More »

What precautions are required during the installation process of spray exhaust cooling towers

The installation process of spray exhaust cooling tower needs to pay attention to the following: 1. Site selection and site preparation The cooling tower should be installed in a place with good ventilation conditions to ensure air circulation and avoid poor ventilation affecting the heat dissipation effect. The installation site should be kept away from

What precautions are required during the installation process of spray exhaust cooling towers Read More »

Where are spray exhaust cooling towers suitable

Spray exhaust cooling towers are suitable for the following locations: Industrial cooling Especially in scenarios where the operating temperature of machines or equipment needs to be reduced, such as the cooling of high-temperature furnaces, furnaces, and other equipment. Spray cooling towers are able to effectively remove the heat generated by the equipment through the evaporation

Where are spray exhaust cooling towers suitable Read More »

What is the difference between air condenser and water condenser?

There are distinct differences between air condensers and water condensers in several ways, and here is a detailed analysis of their differences: Cooling medium: Air condenser: uses air as the cooling medium to remove the heat of condensation of refrigerant vapors through the natural convection or forced flow of air. Water condenser: water is used

What is the difference between air condenser and water condenser? Read More »

How to select the parameters of the spray exhaust cooling tower

There are several aspects to consider in the selection of a spray exhaust cooling tower to ensure that it can meet specific cooling needs. Here are some key parameter selection suggestions, which are represented and summarized in a clear format: 1. Cooling capacity Flow rate (m³/h): Determine the flow rate of the cooling tower according

How to select the parameters of the spray exhaust cooling tower Read More »