{"id":2886,"date":"2024-03-25T15:46:30","date_gmt":"2024-03-25T15:46:30","guid":{"rendered":"https:\/\/www.auagre.com\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/"},"modified":"2024-03-25T15:46:30","modified_gmt":"2024-03-25T15:46:30","slug":"cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo","status":"publish","type":"post","link":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/","title":{"rendered":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_66_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title \" >Tabla de contenidos<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #0066bf;color:#0066bf\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #0066bf;color:#0066bf\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#%C2%BFCuales_son_los_fenomenos_de_averia_mas_comunes_y_sus_soluciones_en_las_enfriadoras\" title=\"\u00bfCu\u00e1les son los fen\u00f3menos de aver\u00eda m\u00e1s comunes y sus soluciones en las enfriadoras?\">\u00bfCu\u00e1les son los fen\u00f3menos de aver\u00eda m\u00e1s comunes y sus soluciones en las enfriadoras?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#El_indicador_de_potencia_del_enfriador_no_se_enciende\" title=\"El indicador de potencia del enfriador no se enciende\">El indicador de potencia del enfriador no se enciende<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#Encienda_el_interruptor_de_encendido_y_el_interruptor_de_la_bomba_de_agua_y_queme_el_fusible\" title=\"Encienda el interruptor de encendido y el interruptor de la bomba de agua y queme el fusible:\">Encienda el interruptor de encendido y el interruptor de la bomba de agua y queme el fusible:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#El_protector_de_sobrecarga_de_la_bomba_de_agua_salta_automaticamente\" title=\"El protector de sobrecarga de la bomba de agua salta autom\u00e1ticamente:\">El protector de sobrecarga de la bomba de agua salta autom\u00e1ticamente:<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#Fallo_del_compresor\" title=\"Fallo del compresor\">Fallo del compresor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#La_indicacion_de_temperatura_del_termometro_salta_hacia_arriba_y_hacia_abajo\" title=\"La indicaci\u00f3n de temperatura del term\u00f3metro salta hacia arriba y hacia abajo\">La indicaci\u00f3n de temperatura del term\u00f3metro salta hacia arriba y hacia abajo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#Fallo_de_baja_presion\" title=\"Fallo de baja presi\u00f3n\">Fallo de baja presi\u00f3n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#Fugas_de_refrigerante_en_sistemas_de_refrigeracion_industrial\" title=\"Fugas de refrigerante en sistemas de refrigeraci\u00f3n industrial\">Fugas de refrigerante en sistemas de refrigeraci\u00f3n industrial<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#Sobrecarga_del_sistema_de_refrigeracion_de_la_enfriadora_industrial\" title=\"Sobrecarga del sistema de refrigeraci\u00f3n de la enfriadora industrial\">Sobrecarga del sistema de refrigeraci\u00f3n de la enfriadora industrial<\/a><\/li><\/ul><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<p>El grado de vac\u00edo del enfriador se controla generalmente a unos 300Pa, pero el grado de vac\u00edo espec\u00edfico debe determinarse seg\u00fan la situaci\u00f3n real y los escenarios de uso. El vac\u00edo ideal deber\u00eda ser de (5-50)*10^-4Pa. Adem\u00e1s, tenga en cuenta que la presi\u00f3n residual dentro del sistema debe ser inferior a 5,332 kPa.<\/p>\n<p>En condiciones de vac\u00edo, el entorno de trabajo de la bomba de aceite es pobre, por lo que es necesario prestar atenci\u00f3n al cambio de presi\u00f3n de aceite del compresor. Seg\u00fan los requisitos, la diferencia entre la presi\u00f3n del aceite y la presi\u00f3n de aspiraci\u00f3n no debe ser inferior a 26,6kPa. Al mismo tiempo, el valor normal de la baja presi\u00f3n de vac\u00edo del enfriador suele estar entre 5-10mmHg. Si el valor de baja presi\u00f3n de vac\u00edo es demasiado alto o demasiado bajo, afectar\u00e1 al funcionamiento normal de la enfriadora.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-2162\" src=\"https:\/\/www.auagre.com\/wp-content\/uploads\/2024\/02\/vacuum-pump.gif\" alt=\"\" width=\"696\" height=\"522\"><\/p>\n<p>La informaci\u00f3n anterior es s\u00f3lo de referencia, y la presi\u00f3n de vac\u00edo espec\u00edfica debe determinarse seg\u00fan el modelo y las especificaciones de la enfriadora y las recomendaciones del fabricante. En funcionamiento real, deben seguirse estrictamente los procedimientos de funcionamiento, y el equipo debe inspeccionarse y mantenerse peri\u00f3dicamente para garantizar su funcionamiento normal y una vida \u00fatil prolongada.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"%C2%BFCuales_son_los_fenomenos_de_averia_mas_comunes_y_sus_soluciones_en_las_enfriadoras\"><\/span>\u00bfCu\u00e1les son los fen\u00f3menos de aver\u00eda m\u00e1s comunes y sus soluciones en las enfriadoras?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Entre los fen\u00f3menos de aver\u00eda m\u00e1s comunes en las enfriadoras y sus soluciones se incluyen:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"El_indicador_de_potencia_del_enfriador_no_se_enciende\"><\/span>El indicador de potencia del enfriador no se enciende<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Puede ser que el fusible no est\u00e9 instalado o que la fuente de alimentaci\u00f3n est\u00e9 mal conectada. La soluci\u00f3n consiste en instalar el fusible adecuado y comprobar si hay problemas con el cableado de alimentaci\u00f3n.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Encienda_el_interruptor_de_encendido_y_el_interruptor_de_la_bomba_de_agua_y_queme_el_fusible\"><\/span>Encienda el interruptor de encendido y el interruptor de la bomba de agua y queme el fusible:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>puede ser un cortocircuito o que el rotor de la bomba de agua est\u00e9 atascado. La soluci\u00f3n es comprobar los cables de control y los cables principales de alimentaci\u00f3n, y aflojar el rotor del motor con un destornillador.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"El_protector_de_sobrecarga_de_la_bomba_de_agua_salta_automaticamente\"><\/span>El protector de sobrecarga de la bomba de agua salta autom\u00e1ticamente:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>el l\u00edmite de corriente del protector se puede ajustar adecuadamente dentro del rango permitido y se puede pulsar el bot\u00f3n de reinicio.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-1017\" src=\"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/faucet-fountain-nature-1684902-1024x682.jpg\" alt=\"faucet, fountain, nature-1684902.jpg\" width=\"803\" height=\"535\" srcset=\"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/faucet-fountain-nature-1684902-1024x682.jpg 1024w, https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/faucet-fountain-nature-1684902-300x200.jpg 300w, https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/faucet-fountain-nature-1684902-768x512.jpg 768w, https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/faucet-fountain-nature-1684902.jpg 1280w\" sizes=\"(max-width: 803px) 100vw, 803px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"Fallo_del_compresor\"><\/span>Fallo del compresor<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Podr\u00eda ser una bobina del compresor abierta, un cortocircuito o la congelaci\u00f3n del compresor. La soluci\u00f3n es sustituir el compresor correspondiente, comprobar si la tuber\u00eda de agua de circulaci\u00f3n est\u00e1 desbloqueada y aumentar el di\u00e1metro de la tuber\u00eda de agua de circulaci\u00f3n para garantizar la circulaci\u00f3n normal del agua.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"La_indicacion_de_temperatura_del_termometro_salta_hacia_arriba_y_hacia_abajo\"><\/span>La indicaci\u00f3n de temperatura del term\u00f3metro salta hacia arriba y hacia abajo<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>puede ser que el term\u00f3metro est\u00e9 fuera de control. La soluci\u00f3n es sustituir el medidor de control de temperatura.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Fallo_de_baja_presion\"><\/span>Fallo de baja presi\u00f3n<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Puede ser una falta de refrigerante o una fuga en la tuber\u00eda. La soluci\u00f3n es suplementar el refrigerante o soldar despu\u00e9s de la detecci\u00f3n de la fuga.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Fugas_de_refrigerante_en_sistemas_de_refrigeracion_industrial\"><\/span>Fugas de refrigerante en sistemas de refrigeraci\u00f3n industrial<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>compruebe primero si el man\u00f3metro de baja presi\u00f3n de la enfriadora industrial tiene presi\u00f3n, si no hay presi\u00f3n, significa que el refrigerante tiene fugas, es necesario comprobar la fuga, compruebe la conexi\u00f3n de cada tubo de cobre, y vea en qu\u00e9 posici\u00f3n est\u00e1 la fuga del refrigerante.<br \/>\nEl compresor de la enfriadora industrial est\u00e1 averiado<\/p>\n<p>La m\u00e1quina muestra que el compresor est\u00e1 averiado. Utilice la pinza amperim\u00e9trica para pinzar los tres cables del compresor y obtener la corriente de trabajo, si los tres son diferentes, el juicio preliminar es que el compresor est\u00e1 mal. La soluci\u00f3n es sustituir el compresor de la enfriadora industrial.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Sobrecarga_del_sistema_de_refrigeracion_de_la_enfriadora_industrial\"><\/span>Sobrecarga del sistema de refrigeraci\u00f3n de la enfriadora industrial<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>En el proceso de uso del enfriador industrial, la temperatura no puede alcanzar el efecto predeterminado, o la temperatura no baja, sino que sube, lo que indica que la potencia del enfriador industrial opcional no es lo suficientemente grande, y la soluci\u00f3n es sustituir el enfriador industrial m\u00e1s grande para alcanzar la temperatura del agua requerida en el proceso de producci\u00f3n.<br \/>\nLa informaci\u00f3n anterior es s\u00f3lo para referencia, cuando el enfriador falla, se recomienda ponerse en contacto con personal de mantenimiento profesional para su inspecci\u00f3n y mantenimiento. Al mismo tiempo, la revisi\u00f3n y el mantenimiento peri\u00f3dicos de la enfriadora tambi\u00e9n son muy importantes para reducir la aparici\u00f3n de aver\u00edas y prolongar la vida \u00fatil del equipo.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El grado de vac\u00edo del enfriador se controla generalmente a unos 300Pa, pero el grado de vac\u00edo espec\u00edfico debe determinarse seg\u00fan la situaci\u00f3n real y los escenarios de uso. El vac\u00edo ideal deber\u00eda ser de (5-50)*10^-4Pa. Adem\u00e1s, tenga en cuenta que la presi\u00f3n residual dentro del sistema debe ser inferior a 5,332 kPa. En condiciones [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[40],"tags":[],"class_list":["post-2886","post","type-post","status-publish","format-standard","hentry","category-sin-categorizar"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v21.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo | AUAGRE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo\" \/>\n<meta property=\"og:description\" content=\"El grado de vac\u00edo del enfriador se controla generalmente a unos 300Pa, pero el grado de vac\u00edo espec\u00edfico debe determinarse seg\u00fan la situaci\u00f3n real y los escenarios de uso. El vac\u00edo ideal deber\u00eda ser de (5-50)*10^-4Pa. Adem\u00e1s, tenga en cuenta que la presi\u00f3n residual dentro del sistema debe ser inferior a 5,332 kPa. En condiciones [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\" \/>\n<meta property=\"og:site_name\" content=\"AUAGRE\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/auagreejector\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-25T15:46:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.auagre.com\/wp-content\/uploads\/2024\/02\/vacuum-pump.gif\" \/>\n<meta name=\"author\" content=\"AUAGRE\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@AuagreEjector\" \/>\n<meta name=\"twitter:site\" content=\"@AuagreEjector\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"AUAGRE\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\"},\"author\":{\"name\":\"AUAGRE\",\"@id\":\"https:\/\/www.auagre.com\/es\/#\/schema\/person\/69824bbda87abf74f69d7bda024f7ad1\"},\"headline\":\"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo\",\"datePublished\":\"2024-03-25T15:46:30+00:00\",\"dateModified\":\"2024-03-25T15:46:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\"},\"wordCount\":810,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.auagre.com\/es\/#organization\"},\"articleSection\":[\"Sin categorizar\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\",\"url\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\",\"name\":\"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo | AUAGRE\",\"isPartOf\":{\"@id\":\"https:\/\/www.auagre.com\/es\/#website\"},\"datePublished\":\"2024-03-25T15:46:30+00:00\",\"dateModified\":\"2024-03-25T15:46:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"homepage\",\"item\":\"https:\/\/www.auagre.com\/es\/inicio\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.auagre.com\/es\/#website\",\"url\":\"https:\/\/www.auagre.com\/es\/\",\"name\":\"AUAGRE\",\"description\":\"Energy saving Ejector vacuum systems and industrial cooling tower solutions\",\"publisher\":{\"@id\":\"https:\/\/www.auagre.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.auagre.com\/es\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.auagre.com\/es\/#organization\",\"name\":\"AUAGRE EJECTOR\",\"url\":\"https:\/\/www.auagre.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.auagre.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/AUAGRE-logos_white-e1699652545112.png\",\"contentUrl\":\"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/AUAGRE-logos_white-e1699652545112.png\",\"width\":652,\"height\":362,\"caption\":\"AUAGRE EJECTOR\"},\"image\":{\"@id\":\"https:\/\/www.auagre.com\/es\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/auagreejector\",\"https:\/\/twitter.com\/AuagreEjector\",\"https:\/\/www.linkedin.com\/company\/auagreejector\"],\"actionableFeedbackPolicy\":\"https:\/\/www.auagre.com\/product\/\",\"correctionsPolicy\":\"https:\/\/www.auagre.com\/product\/\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.auagre.com\/es\/#\/schema\/person\/69824bbda87abf74f69d7bda024f7ad1\",\"name\":\"AUAGRE\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.auagre.com\/es\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/da4752235545d46aa7bfc20b2b8456e725a1509c01807d26f695dc1851ee17aa?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/da4752235545d46aa7bfc20b2b8456e725a1509c01807d26f695dc1851ee17aa?s=96&d=mm&r=g\",\"caption\":\"AUAGRE\"},\"sameAs\":[\"https:\/\/www.auagre.com\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo | AUAGRE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/","og_locale":"es_ES","og_type":"article","og_title":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo","og_description":"El grado de vac\u00edo del enfriador se controla generalmente a unos 300Pa, pero el grado de vac\u00edo espec\u00edfico debe determinarse seg\u00fan la situaci\u00f3n real y los escenarios de uso. El vac\u00edo ideal deber\u00eda ser de (5-50)*10^-4Pa. Adem\u00e1s, tenga en cuenta que la presi\u00f3n residual dentro del sistema debe ser inferior a 5,332 kPa. En condiciones [&hellip;]","og_url":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/","og_site_name":"AUAGRE","article_publisher":"https:\/\/www.facebook.com\/auagreejector","article_published_time":"2024-03-25T15:46:30+00:00","og_image":[{"url":"https:\/\/www.auagre.com\/wp-content\/uploads\/2024\/02\/vacuum-pump.gif"}],"author":"AUAGRE","twitter_card":"summary_large_image","twitter_creator":"@AuagreEjector","twitter_site":"@AuagreEjector","twitter_misc":{"Escrito por":"AUAGRE","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#article","isPartOf":{"@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/"},"author":{"name":"AUAGRE","@id":"https:\/\/www.auagre.com\/es\/#\/schema\/person\/69824bbda87abf74f69d7bda024f7ad1"},"headline":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo","datePublished":"2024-03-25T15:46:30+00:00","dateModified":"2024-03-25T15:46:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/"},"wordCount":810,"commentCount":0,"publisher":{"@id":"https:\/\/www.auagre.com\/es\/#organization"},"articleSection":["Sin categorizar"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/","url":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/","name":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo | AUAGRE","isPartOf":{"@id":"https:\/\/www.auagre.com\/es\/#website"},"datePublished":"2024-03-25T15:46:30+00:00","dateModified":"2024-03-25T15:46:30+00:00","breadcrumb":{"@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.auagre.com\/es\/cuanta-presion-es-normal-para-el-enfriador-al-vacio-de-bombeo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"homepage","item":"https:\/\/www.auagre.com\/es\/inicio\/"},{"@type":"ListItem","position":2,"name":"\u00bfCu\u00e1nta presi\u00f3n es normal para el enfriador al vac\u00edo de bombeo"}]},{"@type":"WebSite","@id":"https:\/\/www.auagre.com\/es\/#website","url":"https:\/\/www.auagre.com\/es\/","name":"AUAGRE","description":"Energy saving Ejector vacuum systems and industrial cooling tower solutions","publisher":{"@id":"https:\/\/www.auagre.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.auagre.com\/es\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.auagre.com\/es\/#organization","name":"AUAGRE EJECTOR","url":"https:\/\/www.auagre.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.auagre.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/AUAGRE-logos_white-e1699652545112.png","contentUrl":"https:\/\/www.auagre.com\/wp-content\/uploads\/2023\/11\/AUAGRE-logos_white-e1699652545112.png","width":652,"height":362,"caption":"AUAGRE EJECTOR"},"image":{"@id":"https:\/\/www.auagre.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/auagreejector","https:\/\/twitter.com\/AuagreEjector","https:\/\/www.linkedin.com\/company\/auagreejector"],"actionableFeedbackPolicy":"https:\/\/www.auagre.com\/product\/","correctionsPolicy":"https:\/\/www.auagre.com\/product\/"},{"@type":"Person","@id":"https:\/\/www.auagre.com\/es\/#\/schema\/person\/69824bbda87abf74f69d7bda024f7ad1","name":"AUAGRE","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.auagre.com\/es\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/da4752235545d46aa7bfc20b2b8456e725a1509c01807d26f695dc1851ee17aa?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da4752235545d46aa7bfc20b2b8456e725a1509c01807d26f695dc1851ee17aa?s=96&d=mm&r=g","caption":"AUAGRE"},"sameAs":["https:\/\/www.auagre.com"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"AUAGRE","author_link":"https:\/\/www.auagre.com\/es\/author\/auagre\/"},"uagb_comment_info":0,"uagb_excerpt":"El grado de vac\u00edo del enfriador se controla generalmente a unos 300Pa, pero el grado de vac\u00edo espec\u00edfico debe determinarse seg\u00fan la situaci\u00f3n real y los escenarios de uso. El vac\u00edo ideal deber\u00eda ser de (5-50)*10^-4Pa. Adem\u00e1s, tenga en cuenta que la presi\u00f3n residual dentro del sistema debe ser inferior a 5,332 kPa. En condiciones&hellip;","_links":{"self":[{"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/posts\/2886","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/comments?post=2886"}],"version-history":[{"count":0,"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/posts\/2886\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/media?parent=2886"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/categories?post=2886"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.auagre.com\/es\/wp-json\/wp\/v2\/tags?post=2886"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}